Determination of life for a polyimide-epoxy alternator insulation systemTests were conducted to predict remaining electrical insulation life of a polyimide epoxy insulated 60 KW, 208 volt homopolar inductor alternator, following completion of 23,130 hours of turbo-alternator endurance tests. The sectioned armature winding of this alternator stator was used as means to evaluate and measure end-life at several aging temperatures for development of an Arrhenius plot. A one-half life rate of 11.3 C was established from these data with a predicted remaining life of 60,000 hours at an armature winding temperature of 248 C and a total life, including endurance test time, of 61,645 hours.
Document ID
19740011591
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Penn, W. B.
(General Electric Co. Erie, PA, United States)
Schaefer, R. F.
(General Electric Co. Erie, PA, United States)
Balke, R. L.
(General Electric Co. Erie, PA, United States)
Date Acquired
September 3, 2013
Publication Date
March 4, 1974
Subject Category
Auxiliary Systems
Report/Patent Number
NASA-CR-134600
Accession Number
74N19704
Funding Number(s)
CONTRACT_GRANT: NAS3-15691
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available