NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Improved Nominal Operating Cell Temperature (NOCT) test procedureA procedure is developed to improve testing of Nominal Operating Cell Temperature (NOCT) as it applies to solar energy conversion modules. NOCT is a direct reflection of module thermal design and is closely related to the representative ambient temperature. It is also a key to array energy production and estimates of module lifetimes. Present NOCT test and evaluation procedures are inconsistent, producing significant scatter. Test refinements would specify a clear sky, the addition of 10% to the insolation level for ground reflection, the addition of a ground emission factor of 0.8 (at 30C ground temperature), an effective wind direction of 135 degrees from the North, and a module tilt of 30 degrees from the horizon.
Document ID
19850024136
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Wen, L.
(Jet Propulsion Lab., California Inst. of Tech. Pasadena, CA, United States)
Berns, D.
(Jet Propulsion Lab., California Inst. of Tech. Pasadena, CA, United States)
Date Acquired
August 12, 2013
Publication Date
October 1, 1984
Publication Information
Publication: Proc. of the 24th Project Integration Meeting
Subject Category
Energy Production And Conversion
Accession Number
85N32449
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.