NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Correlation and analysis of elevon seal test resultsThe heating rate and pressure distributions in and around the elevon coves were correlated. An analytical approach incorporating such a correlation into a thermal structure computer code to examine the elevon seal and cover structure in flight was developed. Emphasis was placed on the design of a thermal model that predicts gas and wall temperatures in the cove area. The elevon cove area was modelled analytically by a parallel plate flow channel, incorporating effects of axial wall conduction, axial and environmental radiant energy exchanges, and effects of laminar and turbulent convection entrance regions. Comparisons were made between computed and measured values of (1) cove wall temperatures; (2) local gas temperature within the cove; and (3) local heating rates.
Document ID
19780003108
Acquisition Source
Legacy CDMS
Document Type
Contractor Report (CR)
Authors
Keshock, E. G.
(Old Dominion Univ. Norfolk, VA, United States)
Date Acquired
September 3, 2013
Publication Date
October 1, 1977
Subject Category
Aircraft Design, Testing And Performance
Report/Patent Number
NASA-CR-155224
Report Number: NASA-CR-155224
Accession Number
78N11051
Funding Number(s)
CONTRACT_GRANT: NSG-1318
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available