Development of an Actuator for Ambient to Cryo ApplicationDuring the qualification campaign of the NIRSpec Instrument Mechanism, the actuator could not achieve the expected life time which was extended during the development phase. The initial design could not be adapted to the requested number of revolutions during that phase. Consequently the actuator needed to be modified such that the function of the mechanism would not be endangered and thus the overall function of the NIRSpec instrument. The modification included the change of the overall actuator design - internal dimensions, tolerances, materials, lubrication and assembly process - while keeping the interface to the mechanism, mass, and function. The lessons learned from the inspection of the failed actuator have been implemented in order to ensure the development and qualification success. The initially available time for this activity was in the range of 6 months to meet the overall program schedule.
IDRelationTitle20100021914Collected WorksProceedings of the 40th Aerospace Mechanisms Symposium20100021914Collected WorksProceedings of the 40th Aerospace Mechanisms Symposium