5 Inch Thick 2219-T87 Plate Low Ductility Investigation - Material Analysis on Broken 2219 Tensile Samples2219-T87 material used on a LOX tank baffle support on Artemis-I showed unusually low fracture elongation. Recent material data indicated 5” thick 2219-T87 plate stock had very low ductility (<1%) in the short transverse direction at the half-thickness location.  Metallurgical analysis performed to understand the root cause that led to the drastic reduction in tensile ductility. The PowerPoint report details the key findings from material analysis by optical and scanning electron microscopy.
Document ID
20210025431
Acquisition Source
Marshall Space Flight Center
Document Type
Other - Interim Report
Authors
Po Chen
(Jacobs (United States) Dallas, Texas, United States)
Matt Medders
(Marshall Space Flight Center Redstone Arsenal, Alabama, United States)
Ellen Rabenberg
(Marshall Space Flight Center Redstone Arsenal, Alabama, United States)
Ching-hua Su
(Marshall Space Flight Center Redstone Arsenal, Alabama, United States)
Date Acquired
December 3, 2021
Publication Date
December 17, 2021
Subject Category
Metals And Metallic Materials
Funding Number(s)
TASK: 981271.08.31.25.30.03
Distribution Limits
Public
Copyright
Public Use Permitted.
Keywords
aluminum alloy 2219
low ductility
theta phase
intergranular fracture