NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Electron beam fluorescence measurements in the Boeing hypersonic shock tunnelThe Calspan electron beam fluorescence (EBF) measurement system is described along with the results of measurements made in hypersonic flow. Numerous self-emitting metallic species were identified, many of which may be associated with an aging/erosion process within the B30HST. Because there were only 16 tunnel runs, it was only possible to obtain spectral measurements over a limited range of wavelengths and time sampling periods. Many spectral features of the flow remain uninvestigated. Because flow self-emission is important to all optical diagnostic techniques, it is recommended that additional spectral studies by performed. The three electron beam-excited species that were identified are nitrogen, helium, and nitric oxide. The high metallic radiation background interfered with attempts to obtain the time-wise variation of N2 density and He radiation with the optical fiber/PMT channels. In the case of the N2 density measurements the result of interference was increased uncertainty. Unfortunately, the interference caused the time-wise He measurements to fail completely. It is recommended that the electron beam be modulated to provide discrimination against the background radiation in future N2 density measurements. Careful data reduction produced useful measurements of N2 vibrational temperature, even though the high background from metallic species significantly increased measurement uncertainty. Perhaps the recommended additional spectral studies would reveal N2(+) First Negative System band-pair regions having less background. Detection of the He arrival was easily accomplished with the spectrometer/array detector system. Because of this, it is recommended that this means of detecting He arrival be used in the future. With proper calibrations of the system an He number density could be obtained. Although the flow conditions were out of limits for the run in which the NO spectrum was recorded, the usefulness of the NO spectrum for determination of free-stream rotational temperature was demonstrated and should be exploited in future experiments. Indeed, based on the strong NO signals, it is recommended that lower resolution NO spectra be obtained to provide a measure of NO vibrational temperature in the same manner that the N2 temperature was obtained.
Document ID
19930004493
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Price, Linwood L.
(Calspan Corp. Arnold AFS, TN, United States)
Williams, W. Dan
(Calspan Corp. Arnold AFS, TN, United States)
Powell, H. M.
(Tennessee Technological Univ. Cookeville., United States)
Date Acquired
September 6, 2013
Publication Date
September 1, 1992
Publication Information
Publication: NASA. Langley Research Center, The 1992 NASA Langley Measurement Technology Conference: Measurement Technology for Aerospace Applications in High-Temperature Environments
Subject Category
Instrumentation And Photography
Accession Number
93N13681
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available